The constraint
Why this one is bridged
Ledbury Mews North runs off Ledbury Road as a cobbled cul-de-sac, entered beneath a building, with the properties either side facing each other across a few metres of setts. There is no pavement to stand a scaffold on and no verge to give up. The mews surface is the access, the parking and the working space all at once, and it belongs to the neighbours as much as it does to the job.
A conventional independent scaffold would have put its standards down into the ground-floor opening and stood them where the entrance is. The unit below was in use and needed to stay that way, so the lifts are carried across the opening on beams instead, with the load taken down through standards set clear on either side. The entrance underneath stays open, and the structure above still gets a full working platform at every lift.
The same tightness decides everything at mews level. Standards sit on sole boards to spread the load across the setts rather than point-load them, they are sleeved in padding where people pass within arm’s reach, and the base is coned and marked out so what is left of the running width reads clearly to anyone coming in under the arch.